Skip to content

Klein Tools Type K pipe clamp, −20 to 100 °C (-4 to 212 °F)

The genuine Klein pipe clamp — and the narrowest temperature range on this shelf, at the highest price of the two clamps.

Klein Tools 69140 type K pipe clamp with its flexible lead

Klein Tools Type K pipe clamp, −20 to 100 °C (-4 to 212 °F)

The genuine Klein pipe clamp — and the narrowest temperature range on this shelf, at the highest price of the two clamps.

Type and plug fit
Type K, stated. "Works with any digital multimeter or clamp meter that measures temperature", and Klein adds that its K-type accessories work with all Klein multimeters and clamp meters that measure temperature "as well as any other brand with meters that measure temperature". The banana plug adapter is NOT in the box: it is Cat. No. 69146, sold separately — which matters because this shelf's introduction says the plug is where fit fails
Probe style
A PIPE CLAMP, which is a fourth style this shelf's introduction does not name. It lists a bead for air, a flat pad for surfaces and a sheathed rod for immersion; a spring clamp that closes round a pipe reads the outside wall of a line you cannot immerse anything in. It is the dominant style in the American relevé for this shelf, because that is how a refrigeration circuit is diagnosed
Stated temperature range
−4 to 212 °F (−20 to 100 °C), stated. That is the NARROWEST range on this shelf: the published Taiss states −40 to 350 °C (-40 to 662 °F), the Nxtop 0 to 1100 °C (32 to 2012 °F), the Klein 69142 beside it 0 to 480 °C (32 to 896 °F), and the ZIBOO clamp that borrows this part number claims −40 to 200 °C (-40 to 392 °F). One hundred degrees Celsius is the top of it, which covers a heating flow and stops below a hot gas line
Stated accuracy
±2%, stated — and then the sentence that makes it honest: "Thermocouple accuracy is dependent on the accuracy of the meter being used." Two probes on this shelf publish a figure at all — this clamp and the ZIBOO — and both add that caveat. It is the right way to put it: a thermocouple generates a voltage, and what turns that voltage into a number is the instrument
Cable length
40 inches, 102 cm, flexible. The ZIBOO clamp states 39.78 inches for the same 102 cm (40.2 in), which is the same lead described to two decimal places. The published Taiss five-pack gives 3 m (10 ft), three times either clamp
Clamp capacity
Pipes from 1/4 to 1-3/8 inch diameter. The ZIBOO clamp claims 1/4 to 1 1/2 inch — an eighth of an inch more. Both listings then add "up to 35 cm (13.8 in)", which is not a pipe diameter at all and appears on both pages
Heat resistance
Not stated separately from the measuring range. Klein positions this as the accessory that "extend[s] working temperature ranges for Klein's HVAC Digital Multimeters and Clamp Meters", and names the rest of the family: high temperature thermocouple wire, temperature probe and banana plug adapter
Amazon reference
B07B2PPBRB
EAN
0092644690679
  • Type K, so it reads correctly on any type K meter
  • A clamp, which is what a pipe actually needs
  • A hundred degrees Celsius is the narrowest ceiling here

Best for: HVAC pipe temperatures on small-bore copper, read through a Klein or any other meter with a temperature function

≈ $27
Check price on Amazon

Specifications

Type and plug fit
Type K, stated. "Works with any digital multimeter or clamp meter that measures temperature", and Klein adds that its K-type accessories work with all Klein multimeters and clamp meters that measure temperature "as well as any other brand with meters that measure temperature". The banana plug adapter is NOT in the box: it is Cat. No. 69146, sold separately — which matters because this shelf's introduction says the plug is where fit fails
Probe style
A PIPE CLAMP, which is a fourth style this shelf's introduction does not name. It lists a bead for air, a flat pad for surfaces and a sheathed rod for immersion; a spring clamp that closes round a pipe reads the outside wall of a line you cannot immerse anything in. It is the dominant style in the American relevé for this shelf, because that is how a refrigeration circuit is diagnosed
Stated temperature range
−4 to 212 °F (−20 to 100 °C), stated. That is the NARROWEST range on this shelf: the published Taiss states −40 to 350 °C (-40 to 662 °F), the Nxtop 0 to 1100 °C (32 to 2012 °F), the Klein 69142 beside it 0 to 480 °C (32 to 896 °F), and the ZIBOO clamp that borrows this part number claims −40 to 200 °C (-40 to 392 °F). One hundred degrees Celsius is the top of it, which covers a heating flow and stops below a hot gas line
Stated accuracy
±2%, stated — and then the sentence that makes it honest: "Thermocouple accuracy is dependent on the accuracy of the meter being used." Two probes on this shelf publish a figure at all — this clamp and the ZIBOO — and both add that caveat. It is the right way to put it: a thermocouple generates a voltage, and what turns that voltage into a number is the instrument
Cable length
40 inches, 102 cm, flexible. The ZIBOO clamp states 39.78 inches for the same 102 cm (40.2 in), which is the same lead described to two decimal places. The published Taiss five-pack gives 3 m (10 ft), three times either clamp
Clamp capacity
Pipes from 1/4 to 1-3/8 inch diameter. The ZIBOO clamp claims 1/4 to 1 1/2 inch — an eighth of an inch more. Both listings then add "up to 35 cm (13.8 in)", which is not a pipe diameter at all and appears on both pages
Heat resistance
Not stated separately from the measuring range. Klein positions this as the accessory that "extend[s] working temperature ranges for Klein's HVAC Digital Multimeters and Clamp Meters", and names the rest of the family: high temperature thermocouple wire, temperature probe and banana plug adapter
Amazon reference
B07B2PPBRB
EAN
0092644690679

What the maker puts in writing

  • “K-Type Thermometer, Pipe Temperature Clamp for HVAC”
  • “Measures temperature from -4 to 212-degrees F (-20 - 100-degrees C) with ±2% accuracy”
  • “Clamps around pipes from 1/4 to 1-3/8-Inch diameter”
  • “40-Inch (102 cm (40.2 in)) long flexible lead”
  • “Works with any digital multimeter or clamp meter that measures temperature”
  • “Thermocouple accuracy is dependent on the accuracy of the meter being used”
  • Banana plug adapter: Cat. No. 69146, separate · $26.98

A clamp is a fourth style

This shelf’s introduction names three.

“A bead for air, a flat pad for surfaces, a sheathed rod for immersion.”

A spring clamp that closes round a pipe is none of those, and it is the style that dominates the American relevé for this shelf.

Because that is how a refrigeration circuit gets diagnosed: suction line, liquid line, two clamps and a delta.

The narrowest range on the shelf

A hundred degrees Celsius at the top.

The published Taiss: −40 to 350 °C (-40 to 662 °F). The Nxtop: 0 to 1100 °C (32 to 2012 °F). The Klein 69142 next to it: 0 to 480 °C (32 to 896 °F).

And the ZIBOO clamp that borrows this part number: −40 to 200 °C (-40 to 392 °F).

One hundred covers a heating flow and a chilled return. It stops below a hot gas discharge line.

Two per cent, with the sentence that matters

“Thermocouple accuracy is dependent on the accuracy of the meter being used.”

A thermocouple generates a voltage. What turns that voltage into a number is the instrument, and on a multimeter the temperature function is usually the least accurate thing it does.

Two probes on this shelf publish a figure at all. Both add that caveat.

The adapter is not in the box

Cat. No. 69146, sold separately.

“The miniature flat plug that connects it is where fit fails.”

A meter with a dedicated thermocouple socket takes this directly. A meter that reads temperature through its 4 mm (0.16 in) inputs does not, and the part that bridges them is a separate order.

The ZIBOO copy includes one.

And “up to 35 cm (13.8 in)”

Which appears on this page and on the ZIBOO page, in both cases after a pipe diameter in inches.

One and three-eighths of an inch is 35 Millimeters.

Thirty-five centimeters is a pipe you would need both arms for.

Availability

On sale at around 27 € on the American Amazon store at the time of checking.

Prices and availability are what Keepa reported on the date this page was updated; both move.

Prices quoted in this text were read on 8 October 2026. The live price is at the top of the page.

What gets asked here

Why is the ZIBOO clamp cheaper and wider-ranging under the same part number?

That is the question this shelf cannot answer for you. The ZIBOO listing opens with "ZIBOO 69140", which is this Klein part number, and its reference field reads 69028+69146 — two more Klein catalog numbers, 69146 being the banana adapter Klein sells separately. It then claims −40 to 392 °F where Klein states −4 to 212 °F, and includes the adapter, for $14.99 against $26.98. Either the copy is built to a wider specification than the original it names, or the specification on the copy is not measured. Nothing on either page settles it.

Does ±2% mean the reading is within 2% of the truth?

No, and the listing says so in its own fifth bullet: "Thermocouple accuracy is dependent on the accuracy of the meter being used." The ±2% describes the probe's contribution. Your meter adds its own error on top, and on a multimeter the temperature function is usually the least accurate thing it does. For an absolute figure that matters, compare against a second probe. For a delta — the difference across a coil, which is what HVAC work actually needs — both errors largely cancel and the number is far better than ±2% suggests.

Will it fit my meter?

If your meter has a type K temperature function, electrically yes — type K is an international standard and the voltage curve is the same everywhere. The question is the connector. This clamp terminates in a thermocouple plug and the banana plug adapter that converts it to two 4 mm (0.16 in) sockets is Cat. No. 69146, sold separately. Meters with a dedicated thermocouple socket take it directly; meters that read temperature through their voltage inputs need the adapter. Check which your meter has before ordering, because that is the whole point this shelf's introduction makes about plugs.

Instruments this fits

All temperature probes