Skip to content

SeKi Ceramic fuses, 10 A, 5 × 20 mm (0.20 × 0.79 in), ten-pack

Ten ceramic fuses with all four specifications stated — size, current, voltage and characteristic — which is the only way a replacement fuse can be chosen.

SeKi ceramic 5 by 20 millimeter fuses in a row on a workbench

SeKi Ceramic fuses, 10 A, 5 × 20 mm (0.20 × 0.79 in), ten-pack

Ten ceramic fuses with all four specifications stated — size, current, voltage and characteristic — which is the only way a replacement fuse can be chosen.

Amazon reference
B0CVXQGP7P (identical on 5 markets)
EAN
4053171962161
Stated dimension or range
5 × 20 mm (0.20 × 0.79 in) ceramic
Fuse rating
10 A / 250 V · time-delay (T)
  • All four figures published: 5 × 20 mm (0.20 × 0.79 in), 10 A, 250 V, time-delay
  • Ceramic bodies, which is what a meter's current input normally specifies
  • A 250 V rating is below what many meters specify for the current input

Best for: The meter whose manual specifies exactly 5 × 20 mm (0.20 × 0.79 in), 10 A, 250 V, time-delay — and no other.

Search Amazon for this model

Specifications

Amazon reference
B0CVXQGP7P (identical on 5 markets)
EAN
4053171962161
Stated dimension or range
5 × 20 mm (0.20 × 0.79 in) ceramic
Fuse rating
10 A / 250 V · time-delay (T)

A fuse is a safety component with four specifications, and this listing gives all four.

What the manufacturer publishes

Ten SeKi G-fuses. A rated current of 10 A and a rated voltage of 250 V. A time-delay tripping characteristic. Dimensions of 5 × 20 mm (0.20 × 0.79 in), ceramic.

The rule, and it has no exceptions

Replace with the exact part the manual specifies. Not the fuse that fits the holder, not the one with the same current, not the glass one from the drawer. Four figures have to match: size, current, voltage and characteristic.

The reason is what the fuse does when a meter is connected across a supply with the dial on amps. That is a near short circuit, and the fuse is the only thing that interrupts it. A fuse of the wrong type either fails to clear or fails destructively.

Where 250 V is not enough

Many instruments specify a higher voltage rating on the current input precisely because of that scenario. If your manual says 600 V or 1000 V, this fuse is not the part, whatever its current rating.

Availability

No such listing: the American Amazon shop answers the reference with a search box rather than a page.

Read from Keepa on the day this page was last revised; stock and price both move without notice.

What gets asked here

Can I fit any fuse that physically fits?

No. This is one of the very few places on this site where a substitution is a safety matter rather than a preference. The manual specifies dimensions, current, voltage and breaking characteristic, and all four have to match.

Why ceramic rather than glass?

A ceramic sand-filled body is specified where the fuse must interrupt a high-energy fault. A glass fuse of the same current rating does not do the same job and can fail violently.

What does "T" or time-delay mean?

The fuse tolerates a brief overload before opening. A fast fuse in a time-delay position blows on every start-up; a time-delay fuse in a fast position does not protect what it was meant to.

Instruments this fits